Aerospace · mechanical design · SolidWorks · FEA · MATLAB

NACA0012 Hinge

Control-Surface Hinge Design & Structural Validation

A compact aerospace mechanical-design study linking a public NACA0012 reference section to a 75%-chord hinge axis, analytical load and stress calculations, SolidWorks mechanism design, local contact FEA and an explicit analytical-to-FEA comparison.

NACA0012 airfoil and control-surface hinge context assembly in SolidWorks
322.33 NDesign hinge reaction
21.63 MPaMATLAB nominal pin stress
35.73 MPaFEA local peak stress
14.08Minimum FEA factor of safety
0.3716 mmMaximum displacement
3.084×10⁻⁴Maximum equivalent strain
1.65×FEA / analytical stress ratio
x/c = 0.75NACA0012 hinge station
Engineering workflow

From aerodynamic reference to load path.

The project was built as one traceable chain rather than as disconnected CAD and simulation exercises. The NACA0012 profile defines the geometric context, the control-surface load model generates the hinge demand, analytical sizing establishes the first structural baseline, and SolidWorks Simulation resolves the local effects around the pin/lug/bracket interfaces.

1 · Reference geometry300 mm NACA0012 profile generated from the standard four-digit thickness equation.
2 · Hinge definitionHinge axis located at 225 mm from the leading edge, corresponding to x/c = 0.75.
3 · Load screeningVelocity and deflection are converted into control-surface force, hinge moment and horn force.
4 · Analytical sizingPin shear/bending, lug bearing, net section and bracket bearing establish nominal margins.
5 · CAD load pathSolidWorks assembly maps the pin, lug, bracket, spar and horn into a physical mechanism.
6 · FEA correlationLocal contact FEA is compared against the nominal analytical stress rather than treated as an isolated result.
System definition

A public geometry with an original hinge study.

The aerodynamic context uses a non-proprietary NACA0012 section with a 300 mm chord. The control-surface break is placed at 75% chord, leaving a 75 mm control-surface chord. The hinge mechanism is an original portfolio load-path demonstrator rather than a reconstruction of proprietary aircraft hardware.

ParameterValue
Main chord300 mm
Hinge station225 mm
Control-surface chord75 mm
Control-surface span600 mm
Control-surface area0.0450 m²
Horn arm40 mm
Pin diameter11.8 mm
Lug hole diameter12.2 mm
Lug thickness18 mm
Bracket ear thickness25 mm each
Aluminum components7075-T6
Hinge pin17-4 PH stainless steel
CAD context

Geometry and mechanism tied to the same hinge axis.

The context assembly is used to show how the abstract 75%-chord aerodynamic hinge station maps into the mechanical subassembly.

Transparent SolidWorks context view showing NACA0012 airfoil and hinge mechanism

Transparent context view linking the NACA0012 profile to the structural hinge assembly.

SolidWorks hinge mechanism with bracket, pin, lug and control-surface structure

Local hinge hardware used for the structural load-path study.

Analytical → FEA

Nominal sizing first. Local stress second.

The maximum screened condition was 50 m/s and 25° control deflection. With the project load model and a 1.5 structural load factor, the design hinge reaction is 322.33 N.

QuantityResult
Dynamic pressure1531.25 Pa
Normal-force coefficient1.7820
Control-surface force122.79 N
Hinge moment3.684 N·m
Horn force92.09 N
Design hinge reaction322.33 N
MATLAB nominal pin von Mises stress21.632 MPa
SolidWorks FEA local peak von Mises stress35.730 MPa
FEA / analytical stress ratio1.65×
Maximum displacement0.3716 mm
Maximum equivalent strain3.084 × 10⁻⁴
Minimum reported FEA FoS14.08
Engineering interpretation: the FEA peak is higher because it resolves local contact, bearing and geometric concentration that the nominal pin calculation intentionally smooths out. The two values therefore represent different fidelity levels rather than a one-to-one verification target.
Evidence

Stress, strain and displacement at the hinge.

The plots below are shown at a deformation scale of 1 where applicable.

SolidWorks Simulation von Mises stress plot showing 35.73 MPa local peak

Local von Mises peak: 35.73 MPa near the load-transfer region.

SolidWorks Simulation displacement plot showing 0.3716 mm maximum displacement

Maximum resultant displacement: 0.3716 mm.

SolidWorks Simulation equivalent strain plot for the hinge region

Maximum equivalent strain: 3.084 × 10⁻⁴.

SolidWorks Simulation factor of safety plot for the hinge assembly

Minimum reported FEA factor of safety: 14.08. Extremely large values in nearly unstressed regions are not used as design metrics.

What the comparison means

FEA is not being used to decorate the CAD.

The analytical model answers the first sizing question quickly and transparently. The FEA model then asks a different question: where does the real geometry concentrate the load once pin/lug/bracket contact is represented?

The result is a 1.65× increase from nominal analytical pin stress to local FEA peak stress. That difference is kept in the project rather than tuned away because it illustrates the practical role of local simulation after hand/analytical sizing.

The final investigated static configuration remains above the project screening target FoS of 3.0 within the stated model assumptions.

Claim boundary

What this project does not prove.

This is a portfolio-level engineering study, not flight-hardware substantiation or certification evidence. It does not include fatigue or spectrum loading, full airframe/control-surface flexibility, detailed fastener preload, tolerance sensitivity, nonlinear material behaviour, certification load cases or a documented mesh-convergence study.

The hinge assembly demonstrates the mechanical load path and analysis workflow. It is not claimed to be a packaging-optimized internal hinge installation inside a real NACA0012 wing.

A lightweight 2-D SU2 aerodynamic check was used during the broader workflow, but the exact original SU2 configuration, mesh and coefficient-history files were not available in the final publishing workspace. No solver output has been fabricated to fill that gap.

Reference basis: the NACA0012 geometry is based on the public NACA four-digit airfoil definition and NACA Report 460. SU2 is referenced only as an open-source aerodynamic workflow used during the project.